| Спецификация | Attribute 1 — Grade: Pure Titanium TA1/TA2, TC4/Gr5 Attribute 2 — Standard: Available to ASTM F67 / F136 on request Attribute 3 — Form: Sheet, Plate, Sample Material Attribute 4 — Surface & Condition: |
|---|---|
| Справочная цена | $40.00 – $70.00 |
Описание продукции: Supplier Medical grade titanium plate in pure titanium and TC4 (Gr5). Available to ASTM F67 / F136 on request, with full traceability and MTC. Baoji China.
Biocompatible Titanium Plate for medical components and instruments.
生物相容性钛板,适用于医疗器械部件与植入物加工。
Titanium is chosen for medical work because it is light, corrosion-resistant and biocompatible. We supply plate in pure titanium grades and TC4, with traceability documentation that supports the paperwork side of regulated supply.
钛材因轻质、耐蚀、生物相容而被医用领域选用。我们供应纯钛牌号与 TC4 板材,可提供满足规范追溯要求的材质文件,配合下游客户的合规流程。
Overview
For medical applications the material is only half the story. The paperwork — chemistry, melt source, heat number, dimensions and test results — is what lets a component manufacturer satisfy its own quality system and its customer audits. We keep lot-level traceability on every plate so the documentation and the material stay linked from dispatch to arrival.
Pure titanium grades are most often used where formability and corrosion resistance matter: instrument bodies, handles, and components that are machined rather than loaded. TC4 (Gr5) is specified when strength and fatigue resistance enter the picture, such as structural implant components. Which grade is appropriate depends on the intended application, not on a generic label of medical grade.
We supply material against ASTM F67 and ASTM F136 where requested, and can arrange additional inspection or documentation. It is worth being clear about one boundary: the final conformity of a finished implant or device remains the responsibility of the component manufacturer, and we are transparent about where our responsibility begins and ends.
Grade guidance
Titanium does not corrode in body-fluid environments, which is the basic reason it is used for implants and long-term instruments.
Each plate carries a heat/lot number matched to its MTC, which matters when your customer audits the material chain.
Pure titanium grades machine cleanly for instruments; TC4 is used where strength and fatigue resistance are required.
Specifications
| Grades | Pure titanium (per ASTM F67) · TC4/Gr5 (per ASTM F136 on request) |
|---|---|
| Standard | ASTM F67 / ASTM F136 (other specs reviewed case by case) |
| Form | Sheet and plate, cut to size |
| Thickness | 0.5–30mm (custom on request) |
| Surface | Pickled / Bright / Polished (per application) |
| Traceability | Heat/lot number matched to MTC |
| Documentation | MTC with every batch; EN 10204 3.1 available |
| Note | Final conformity remains the responsibility of the component manufacturer |
Material supplied to ASTM F67 or F136 is identified and documented against the requested specification; the purchase specification should be confirmed before cutting.
Supply
For medical-grade supply, the paperwork is as important as the plate. We keep lot-level traceability and can arrange additional inspection or documentation on request. Final conformity to medical standards remains the responsibility of the component manufacturer.
Custom service
Send us the material specification and part drawing. We confirm the grade and documentation requirements before cutting, and we are straightforward about what we can certify and what must be verified by the component manufacturer downstream.
Applications
Bone plates, screws and structural implant components.
Corrosion-resistant instrument bodies and handles.
Frames and components requiring biocompatibility.
Buying guide
Confirm the end application before choosing the grade. Pure titanium is the usual choice for corrosion resistance and formability in instruments; TC4 is for parts where strength and fatigue resistance matter. Telling us whether the part is an instrument, an implant component, or something else lets us recommend the right grade instead of guessing from a generic request.
Agree the documentation package up front. Medical supply chains usually require the MTC to carry specific fields and the inspection records to follow a particular format. Sending us the purchase specification before cutting avoids rework and re-issue later.
Keep the boundary clear. We supply and document the raw material; we do not certify finished implants or devices. Any downstream processing, finishing, sterilization and final release remains with the component manufacturer, and we are happy to explain exactly what our certificate covers.
FAQ
Tell us grade, size and quantity. We reply within 24 hours.
WhatsApp +86 188 2967 9311Or email sales@sxqytd.com | Tel +86-917-355-7966
Floor 4, Building 4, No. 188 Gaoxin Avenue, High-tech Zone, Baoji City, Shaanxi, China.
Manufacturer of titanium, nickel and zirconium materials, based in Baoji Titanium Valley.
Опишите ваши требования — марка, размер и количество. Ответим в течение 24 часов.
Предпочитаете чат? WhatsApp +86 188 2967 9311 или напишите на sales@sxqytd.com.
Контактное лицо: Wang Xiaoning
Телефон: +86-917-355-7966
Эл. почта: sales@sxqytd.com
WhatsApp: +86 188 2967 9311
Компания: Shaanxi Qianyi Tuoda Technology Co., Ltd
Адрес: Floor 4, Building 4, No. 188 Gaoxin Avenue, High-tech Zone, Baoji City, Shaanxi Province, China