Добро пожаловать в Shaanxi Qianyi Tuoda Technology Co., Ltd
EnglishРусский中文
  • Fine Titanium Wire for Medical Mesh \| F67 Gr1/Gr2 & F136 Gr23 ELI, 0.05–0.5mm, Electropolished, ISO 13485-Chain MTC
Fine Titanium Wire for Medical Mesh \| F67 Gr1/Gr2 & F136 Gr23 ELI, 0.05–0.5mm, Electropolished, ISO 13485-Chain MTC

Fine Titanium Wire for Medical Mesh \| F67 Gr1/Gr2 & F136 Gr23 ELI, 0.05–0.5mm, Electropolished, ISO 13485-Chain MTC

Спецификацияfine titanium wire medical mesh, ASTM F67 Gr1 titanium mesh wire, F136 Gr23 ELI medical weave wire, 0.1mm titanium wire mesh, electropolished titanium wire medical, titanium dutch weave mesh wire, ISO

Описание продукции: Fine titanium wire for medical mesh from Baoji — ASTM F67 Gr1/Gr2 (CP) and F136 Gr23 ELI, Ø0.05–0.5mm, ±0.002mm tolerance, bright/electropolished, ultrasonic-clean, lot-traceable MTR. For precision we

Запросить цену Связаться с отделом продаж

Обзор продукции

Fine Titanium Wire for Medical Mesh | ASTM F67 Gr1/Gr2 & F136 Gr23 ELI, 0.05–0.5mm, Electropolished, Lot-Traceable

Meta Description: Fine titanium wire for medical mesh from Baoji — ASTM F67 Gr1/Gr2 (CP) and F136 Gr23 ELI, Ø0.05–0.5mm, ±0.002mm tolerance, bright/electropolished, ultrasonic-clean, lot-traceable MTR. For precision weave, Dutch weave, braid-reinforced tubing, implant-grade mesh. Medical chain isolated from industrial stock.

Overview — Mesh Wire Is a Weaving Problem, Not a Welding Problem

Medical mesh lives or dies on wire consistency, not on a "titanium" label. A 0.1mm wire that drifts ±0.01mm will show up as:

  • uneven aperture
  • local necking → broken warp during weave
  • elliptical cross-section → poor node closure in Dutch weave
  • surface particles → biofilm risk in implant use

We supply fine titanium wire for medical mesh in two clean chains:

  • ASTM F67 — unalloyed CP titanium (Gr1/Gr2), max ductility, corrosion passive film, non-load-bearing mesh / filtration / dental / soft-tissue containment
  • ASTM F136 — Ti-6Al-4V ELI (Gr23), high strength + fracture toughness, load-bearing implant mesh, orthopedic containment, cranial/MaxFax structures

Industrial B863 Gr1 is NOT shipped as F67 unless the PO names F67 + medical clean chain. No silent upgrade, no silent downgrade.

Grade Selection for Mesh

Grade Standard Why mesh uses it Typical mesh use
Gr1 (CP Ti) ASTM F67 Softest, best drawability, ultra-low springback Fine filtration, Dutch weave, soft-tissue / dental mesh
Gr2 (CP Ti) ASTM F67 Balanced strength + corrosion General medical sieve, pharma filter roll
Gr23 ELI ASTM F136 / ISO 5832-3 High strength, low interstitial, fatigue-resistant Implant-grade structural mesh, bone-graft containment

Rule: non-implant / external-contact filtration → F67 Gr1. Load-bearing implant → F136 Gr23, with device master-file traceability.

Diameter & Tolerance (The Real Mesh Spec)

Range Tolerance Form Use
0.05–0.10 mm ±0.002 mm Level-wound spool 120–200 mesh Dutch weave, micro filtration
0.10–0.25 mm ±0.003 mm Spool / coil 60–100 mesh plain/twill, pharma screen
0.25–0.50 mm ±0.005 mm Spool / straight on request 40–80 mesh implant frame mesh

Multi-pass diamond-die drawing; roundness checked per lot. Elliptical wire rejected before spooling — it is the #1 cause of aperture drift in fine mesh.

Surface & Cleanliness

  • Bright annealed → pickled → ultrasonic clean (particle residue controlled)
  • Electropolish option: Ra ≤0.2 μm (implatable-surface grade)
  • No drawing lube, no graphite, no glove-oil transfer
  • Cleanroom-pack optional: ISO 11607-1 peel pouch + tyvek + desiccant
  • Passivation per ASTM F86 / ISO 10993 preparation on request

Surface is not cosmetic. For mesh in body-fluid contact, Ra and particulate load drive cytocompatibility far more than the brochure "99.5% Ti" line.

Mechanical Reference (Annealed)

Grade UTS YS Elong
F67 Gr1 ≥240 MPa ≥170 MPa ≥24%
F67 Gr2 ≥345 MPa ≥275 MPa ≥20%
F136 Gr23 ≥860 MPa ≥795 MPa ≥10%

Values per ASTM F67 / F136 annealed min. Fine-wire measured values reported on MTR per lot; spring-temper variants quoted PO-stated.[9](@ref)

Weave Compatibility

  • Plain weave: 0.05–0.15mm, stable tension, low open-area loss
  • Twill weave: 0.15–0.30mm, higher mesh count, smoother surface
  • Dutch weave (plain/twill): 0.05–0.12mm warp, tight filtration rating
  • Braided sleeve / catheter reinforcement: level-wound spool, zero tangle

Tell us weave type + mesh count + warp/weft diameter — we match cast/helix so the warping machine does not fight the wire.

Traceability & Compliance

  • Melt lot → rod → drawn wire → spool, one heat No.
  • MTR (EN 10204 3.1 equivalent, mill-authorized): chemistry (O/H/N/C), tensile, diameter scan
  • ASTM F67 / F136 cited on cert line — not "medical-grade" vague stamp
  • ISO 13485-chain production reviewed on request; GMP-clean pack PO-stated
  • 3.2 (SGS/BV/TÜV) witness PO-fronted
  • F67 and F136 NEVER share a spool line with industrial B863 stock

Packaging

  • Level-wound plastic spool (DIN 125 / D200 custom)
  • Vacuum foil + desiccant + tyvek barrier for clean-pack
  • Peel-pouch (ISO 11607) for implant-chain lots
  • Lot tag: grade + standard + Ø + heat + clean-chain ID
  • Pre-ship photo: spool face + seal + tag

Stock Honesty

Chain Status
F67 Gr1 0.10–0.30mm Qualified heats rotate; cut/pack after lot confirm
F67 Gr2 0.15–0.50mm Project heats, PO-fronted
F136 Gr23 0.15–0.50mm VAR double melt, ELI chain, separate schedule
Sub-0.10mm / electropolish / cleanroom Custom draw + clean line, lead quoted before PI

No "all micron sizes same-day". Medical chain = scheduled, not rushed.

Enquiry Template (Copy-Paste)

End use: filtration / implant / dental / braid-reinforce ___
Standard: ASTM F67 Gr1/Gr2 / ASTM F136 Gr23 ___
Diameter: ___ mm (warp ___ / weft ___ if different)
Tolerance: ±0.002 / ±0.003 / per drawing
Surface: bright / pickled / electropolish Ra___μm
Weave: plain / twill / Dutch / braid ___
Clean pack: ISO 11607 peel pouch Y/N
Melt: VAR double / triple ___
Cert: MTR 3.1 / 3.2 (TPI: ___)
Spool: DIN125 / D200 / custom wind ___
Qty: ___ km / ___ spools
Incoterm: EXW Baoji / FOB Shanghai / DAP ___

FAQ — Fine Titanium Wire for Medical Mesh

Q1: Can industrial Gr1 replace F67 for mesh?
A: Chemically close, but not document-equivalent. Implant/device filing needs F67 on the cert line + medical clean chain. We keep the two chains separate.

Q2: Smallest diameter you draw?
A: 0.05mm on medical ELI/drawing chain; sub-0.10mm quoted with draw schedule + yield loss disclosed.

Q3: Electropolish necessary?
A: For implant-surface contact, yes — Ra ≤0.2μm reduces particulate adhesion. External filtration can run bright-pickled.

Q4: Will it break on the loom?
A: Roundness + cast control is what prevents warp breakage. We reject elliptical lots before spooling, not after your loom stalls.

Q5: Gr23 too stiff for fine mesh?
A: Stiffer than Gr1, yes. 0.15–0.30mm Gr23 weaves well with correct tension; below 0.10mm Gr1/F67 is the safer draw.

Q6: MTR real interstitials?
A: Yes — O/H/N/C measured per lot, F136 O≤0.13%.

Q7: Cleanroom pack?
A: ISO 11607 peel pouch + tyvek + desiccant, PO-stated. Not default on industrial orders.

Q8: Dutch weave warp/weft different Ø?
A: Common. Send warp + weft diameters; we supply two spools, one heat family, separate tags.

Q9: Biocompatibility test (ISO 10993)?
A: Material meets F67/F136 chemistry + MTR; full device-biocompatibility dossier is customer-device responsibility. We supply material-level data pack to support it.

Q10: Lead time?
A: F67 common Ø → lot-confirmed, same working week. F136 ELI / sub-0.10mm / electropolish → melt+clean schedule quoted before PI.

Request a Quote

Email: sales@[yourdomain].com

Send end-use + standard + Ø (warp/weft) + weave + surface + clean-pack need. Reply in 24h: heat status, EXW/FOB price, MTR type, dispatch date.


About: Baoji Titanium Valley fine-wire line for medical mesh. ASTM F67 Gr1/Gr2 and F136 Gr23 ELI, Ø0.05–0.5mm, ±0.002mm class, bright/electropolished, ultrasonic-clean, lot-traceable ingot-to-spool. Two chains — CP medical and ELI implant — never blended with industrial B863. Draw to the loom, not to the slogan.

Получить бесплатное предложение

Опишите ваши требования — марка, размер и количество. Ответим в течение 24 часов.

Captcha code

Предпочитаете чат? WhatsApp +86 188 2967 9311 или напишите на sales@sxqytd.com.

Контактная информация

Контактное лицо: Wang Xiaoning

Телефон: +86-917-355-7966

Эл. почта: sales@sxqytd.com

WhatsApp: +86 188 2967 9311

Компания: Shaanxi Qianyi Tuoda Technology Co., Ltd

Адрес: Floor 4, Building 4, No. 188 Gaoxin Avenue, High-tech Zone, Baoji City, Shaanxi Province, China

Отправить запрос