| Спецификация | titanium bar medical implant grade 23, Gr23 Ti-6Al-4V ELI bar F136, ASTM F136 vs B348 Grade 23 difference, R56401 implant titanium rod, oxygen 0.13% ELI traceability, medical titanium bar heat number |
|---|---|
| Справочная цена | $50.00 – $80.00 |
Описание продукции: Titanium bar for medical implant Grade 23 (Ti-6Al-4V ELI, R56401) to ASTM F136. O≤0.13%, low interstitials, ingot-to-bar heat traceability, UT per PO, EN 10204 3.1 for DMR. Not industrial B348 passed
Meta Description: Titanium bar for medical implant Grade 23 (Ti-6Al-4V ELI, R56401) to ASTM F136. O≤0.13%, low interstitials, ingot-to-bar heat traceability, UT per PO, EN 10204 3.1 for DMR. Not industrial B348 passed as implant. Quote with standard edition.
Gr23 (UNS R56401, Ti-6Al-4V ELI, 国标 TC4ELI) is the low-interstitial version of Ti-6Al-4V. The whole point of ELI is not a cleaner label — it's lower oxygen/nitrogen/hydrogen so the bar resists brittle crack initiation under cyclic load. That's why permanent implants (bone screws, spinal rods, hip stems, dental abutments) spec F136, not B348.
We don't sell "medical-grade vibes". We supply bar against the standard your DMR names: ASTM F136 for implant wrought ELI; ASTM B348 Gr23 only where the PO explicitly accepts industrial bar basis. The cert carries real numbers — O, N, H, Fe — not "complies".
| Item | ASTM B348 Gr23 | ASTM F136 (implant) |
|---|---|---|
| Scope | Industrial bar/billet, ELI chemistry | Wrought Ti-6Al-4V ELI for surgical implants |
| UNS | R56407 (B348 listing) / R56401 referenced | R56401 |
| O max | 0.13% | 0.13% |
| H max | 0.0125% (confirm B348 edition) | ≤0.012% (edition-dependent) |
| UTS min (annealed) | 828 MPa (B348 ref.) | 860 MPa (F136) |
| YS min | 759 MPa | 795 MPa |
| RA min | 15% | 25% |
| Microstructure / UT | PO-dependent | Implant acceptance + UT/micro review per spec |
| Use | Instruments, non-implant, R&D | Permanent implant DMR material |
Key sentence for QA: A heat that passes B348 can still fail F136 on oxygen/iron/UT alone. B348 is a supply-chain standard; F136 is an implant-acceptance standard. Don't let a trader swap them.
| Element | Gr23 ELI (F136/B348 ELI) | Why it's capped |
|---|---|---|
| O | ≤0.13% | High O = brittle, lower fracture toughness |
| N | ≤0.03–0.05% (edition) | Alpha stabiliser, raises strength but kills ductility |
| H | ≤0.012–0.0125% | Hydride cracking risk in service |
| Fe | ≤0.25% | Excess Fe → beta flecks, inhomogeneous microstructure |
| C | ≤0.08% | Carbide control |
| Al / V | 5.5–6.5 / 3.5–4.5% | Alloy identity |
ELI = Extra Low Interstitials. The alloy is "the same Ti-6Al-4V" only on the Al/V line — everywhere that controls crack growth, it is not the same material.
| Property | Value (annealed) |
|---|---|
| UTS | ≥860 MPa (F136); ≥828 MPa (B348 Gr23 ref.) |
| 0.2% YS | ≥795 MPa (F136) |
| Elongation | ≥10% |
| Reduction of area | ≥25% (F136) |
| Density | 4.43 g/cm³ |
| Modulus | ~105–116 GPa |
| Beta transus | ~975–995°C (process control reference) |
Values are standard-reference floors, not guaranteed for every section. Final acceptance = current standard edition + section size + PO acceptance matrix.
| Form | Range | Condition | Status |
|---|---|---|---|
| Round bar | Φ3–200mm common; >200mm forged project | Mill annealed / duplex annealed on request | Heat-confirm |
| Peeled / ground | h9 default; h7/h6 project | Centerless ground | To order |
| Cut blank | 50–6000mm | Sawn / faced | Same-week on confirmed heat |
| Square / hex | Per drawing | Peeled/ground | Project |
Honest note: implant ELI bar is not "click-buy commodity". We confirm melt route + lead + cert type before PI — because a wrong heat here is a recall, not a return.
Grade: Gr23 / TC4ELI / R56401 ___ Standard: ASTM F136 / F136+ISO 5832-3 / B348 Gr23 (state if industrial basis OK) ___ Melt route: VAR double / triple ___ Diameter: Φ___ mm (h9/h7/h6 or per drawing) Length: ___ mm × ___ pcs Condition: mill annealed / duplex annealed Ends: sawn / faced / chamfer UT: F136 level ___ / E2375 ___ / none Micro: equiaxed alpha-beta report? Y/N Cert: EN 10204 3.1 / 3.2 (TPI: ___) DMR support docs: chemistry numeric / tensile / RA / grain ___ Clean pack: double-bag / cleanroom ___ Port: ___ (FOB Shanghai default)
Q1: Can I use industrial Gr5 B348 for an implant?
A: No. F136 mandates ELI chemistry + implant acceptance. B348 Gr5 has higher O ceiling — disqualified on interstitials alone.
Q2: Is "Grade 23" on the cert enough?
A: Not unless the MTR shows actual O/N/H numbers and the named standard (F136 or B348 Ed.). "Grade 23 compliant" without values = reject.
Q3: B348 Gr23 vs F136 — same bar?
A: Same ELI chemistry window, different acceptance lineage. F136 adds implant UT/micro/traceability layers B348 doesn't mandate.
Q4: Oxygen really 0.13% max?
A: Yes for ELI. Above that it drifts toward standard Gr5 interstitial behavior — toughness loss under cyclic load.
Q5: Do you melt in-house?
A: We confirm the melt route (VAR) with the mill of record; heat chain ingot→bar documented. We don't relabel trader stock as "own-melt implant".
Q6: ISO 13485?
A: State your QMS evidence requirement in PO. We supply material certs + traceability for your DMR; the device master record stays with the license holder.
Q7: UT level for spinal rod?
A: F136-equivalent acceptance, FBH calibre per PO. Write the level — don't leave "supplier default".
Q8: h7 ground ELI blank?
A: Yes, common sizes to order; ground after anneal, straightness + Ra reported.
Q9: Dispatch?
A: Heat-confirmed ELI lead stated honest (not "same-day commodity"). Air for clinical trial line at buyer cost.
Q10: Sample for validation lot?
A: Small cutoff from same heat, courier cost, deductible from validated PO — with full MTR, never "visual OK".
Email: sales@[yourdomain].com
Send standard edition + diameter × length × qty + cert type. Reply within 24h: confirmed melt route, lead, EXW/FOB, UT scope, DMR doc list.
About: Baoji Titanium Valley supplier. Gr23 (Ti-6Al-4V ELI, R56401) bar for medical implant applications — ASTM F136 route on PO, ingot-to-bar heat traceability, O≤0.13% ELI chemistry, UT/micro per spec, EN 10204 3.1 for your DMR. We don't pass industrial B348 as implant. The cert carries numbers, not adjectives.
| Question | Answer |
|---|---|
| Permanent implant? | Gr23 ELI + F136. No Gr5 substitution. |
| Instrument / fixture / R&D? | Gr5 B348 acceptable if QA signs |
| Fatigue-notched + non-inspectable? | Gr23 ELI |
| Static strength, cost-driven? | Gr5 F1472 route where standard interstitial allowed |
Опишите ваши требования — марка, размер и количество. Ответим в течение 24 часов.
Предпочитаете чат? WhatsApp +86 188 2967 9311 или напишите на sales@sxqytd.com.
Контактное лицо: Wang Xiaoning
Телефон: +86-917-355-7966
Эл. почта: sales@sxqytd.com
WhatsApp: +86 188 2967 9311
Компания: Shaanxi Qianyi Tuoda Technology Co., Ltd
Адрес: Floor 4, Building 4, No. 188 Gaoxin Avenue, High-tech Zone, Baoji City, Shaanxi Province, China