Добро пожаловать в Shaanxi Qianyi Tuoda Technology Co., Ltd
EnglishРусский中文
  • Pure Titanium Wire Gr2 for Chemical Repair \| ERTi-2 AWS A5.16, TIG/MIG, Argon-Clean, MTC 3.1, Baoji Stock
Pure Titanium Wire Gr2 for Chemical Repair \| ERTi-2 AWS A5.16, TIG/MIG, Argon-Clean, MTC 3.1, Baoji Stock

Pure Titanium Wire Gr2 for Chemical Repair \| ERTi-2 AWS A5.16, TIG/MIG, Argon-Clean, MTC 3.1, Baoji Stock

Спецификацияpure titanium wire Gr2 chemical repair, ERTi-2 AWS A5.16 repair wire, Gr2 titanium vessel weld repair, chloride service titanium filler wire, heat exchanger titanium welding wire, ERTi-2 TIG rod MIG s

Описание продукции: Pure Gr2 titanium welding wire for chemical equipment repair — ERTi-2 per AWS A5.16, TIG rod + MIG spool, bright-pickled, argon-clean, EN 10204 3.1 with measured O/H/N/C. For chloride/brine/heat-excha

Запросить цену Связаться с отделом продаж

Обзор продукции

Pure Titanium Wire Gr2 for Chemical Repair | ERTi-2 AWS A5.16, TIG/MIG, Argon-Clean, MTC 3.1

Meta Description: Pure Gr2 titanium welding wire for chemical equipment repair — ERTi-2 per AWS A5.16, TIG rod + MIG spool, bright-pickled, argon-clean, EN 10204 3.1 with measured O/H/N/C. For chloride/brine/heat-exchanger/vessel re-welds. Lot confirmed before PI; no ghost shelf, no minima-only cert.

Overview — Repair Welds Fail on Two Things: Wire Identity + Shielding

Chemical plant re-welds on Gr2 shells, tube sheets, and piping are not a "buy any titanium wire" job. The failure modes are predictable:

  • Wrong filler class → undermatching/overmatching vs WPS, requalification
  • Interstitial pickup (O/N/H) → blue bead, alpha-case, brittle HAZ, delayed crack
  • No back purge → root side oxidises, chloride attacks start at the root
  • "Minima-only" cert → QA cannot correlate deposit chemistry to WPS

Our Gr2 repair wire is supplied as ERTi-2 per AWS A5.16 — commercially pure, not alloyed, matched to Gr2 base metal for corrosion-service re-welds. Measured interstitials on every MTC 3.1. Lot locked before PI.

Why ERTi-2 for Gr2 Chemical Repair

Point Reality
Match to base Gr2 shell/tube/tubesheet → ERTi-2 is the standard filler per WPS; ERTi-1 acceptable where higher ductility is specified
Corrosion service Chlorides, brine, wet Cl₂, seawater, organic acids — CP Ti passive film restored only if weld is clean
Strength UTS ≥345 MPa, YS ≥275 MPa (annealed deposit min) — enough for chemical static equipment
Cost Lower than Gr5, correct choice when strength is not the limiting factor
Weldability GTAW/TIG standard; GMAW/MIG for thicker sections; plasma for long seams

Note: if the original WPS names ERTi-1, follow the WPS — we supply both, but the WPS decides, not the warehouse.

Chemistry Band (ERTi-2 / AWS A5.16)

Element Max / Range
Ti Balance
O ≤0.16% (class band; MTC reports measured value)
Fe ≤0.20–0.30% (per revision)
C ≤0.05%
N ≤0.015%
H ≤0.008%

MTC 3.1 lists measured O/H/N/C + Fe + tensile — not "complies with max". Repair QA needs numbers, not adjectives.

Repair Scene Stock Menu

Form Ø Use on site
TIG straight rod 1.6 / 2.0 / 2.4 / 3.2 mm Shell patch, tube sheet, root pass, field GTAW
MIG spool D200 0.8 / 1.0 / 1.2 / 1.6 mm Thick-wall vessel, long seam, automatic carriage
Coil (feeder) 1.0–1.6 mm Orbital/automatic repair on piping

Core Ø 1.6/2.0/2.4mm TIG + 1.2mm MIG on qualified heats — lot confirmed before PI.

Field Repair Discipline (Wire Side + Process Side)

Wire we control; process we align to, we don't pretend to weld for you:

  • Argon purity: ≥99.99% (99.995%+ for critical service), dew point ≤-40°C
  • Front shield: gas lens / large cup + trailing shield on long seams
  • Back purge: root dam / inflatable bladder; keep purging until HAZ <315°C
  • Cleaning: acetone/alcohol degrease, dedicated Ti brush only — no steel wool, no carbon-steel tool crossover
  • Colour check: silver / light straw = OK; blue/purple = re-clean and redo; alpha-case must be removed
  • Wire handling: keep sealed until feed; cut rod ends capped; never lay wire on shop floor

A clean ERTi-2 spool cannot save a leaky purge. We say it upfront so the re-repair ticket doesn't come back to us.

Where It Repairs Well

  • Chlor-alkali cells, anode hangers, cathode structures
  • Ti tube bundles / shell-and-tube heat exchangers
  • Reaction vessels, towers, brine tanks
  • Seawater RO / desalination piping
  • Paper bleach washers, wet chlorine ducts
  • Patch welds on Gr2 shells where WPS permits ERTi-2

Traceability for Repair Records

  • Every spool/rod: AWS class + Ø + lot/heat + manufacturer ID flag-tagged
  • EN 10204 3.1: measured chemistry + tensile + lot-to-ingot
  • Sealed cert pouch with spool; 3.2 (SGS/BV/TÜV) PO-fronted
  • ERTi-2 (filler) cert line never merged with B863 base-wire cert
  • Pre-ship photo: spool face + seal + lot tag for your shutdown file

Packaging for Site Dispatch

  • Vacuum foil + desiccant + aluminium barrier
  • TIG rod: PE/kraft tube, ends capped, flag per rod
  • MIG: D200 plastic spool, precision layer-wind, no cross-lap
  • Outer: plywood case / antistatic carton, "DRY / NO OIL / ARGON-CLEAN"
  • Express or air-cargo friendly for shutdown windows

Enquiry Template (Copy-Paste)

Equipment: vessel / heat exchanger / pipe / tubesheet ___
Base metal: Gr2 (confirm WPS) ___
WPS class required: ERTi-2 / ERTi-1 ___
AWS A5.16 rev: ___
Form: TIG rod ___mm / MIG spool ___mm (D200/D300)
Qty: ___ rods / ___ spools
Service fluid: chloride / brine / wet Cl2 / seawater ___
Purge plan: back purge Y/N, argon purity ___
Cert: 3.1 / 3.2 (TPI: ___)
Urgency: shutdown date ___ / sample first ___
Incoterm: EXW Baoji / FOB Shanghai / DAP ___

FAQ — Gr2 Pure Titanium Repair Wire

Q1: ERTi-2 or ERTi-1 for Gr2 repair?
A: Follow the WPS. ERTi-2 is the standard CP filler for Gr2; ERTi-1 where higher ductility is specified. We don't substitute without the WPS line.

Q2: Can it handle chloride service?
A: Yes — CP Gr2/ERTi-2 is chosen for chloride/brine/seawater. But only if the weld stays argon-clean; a contaminated bead loses the passive film locally.

Q3: Blue bead after weld — wire fault?
A: Almost always purge/contamination, not chemistry. Wire ships argon-clean; shielding is site-side. Re-clean HAZ, remove alpha-case, re-weld.

Q4: MTC real numbers?
A: Yes — measured O/H/N/C/Fe + tensile on 3.1. No minima-only stamp for repair orders.

Q5: Fast for shutdown?
A: Core Ø on qualified heats — lot confirmed, same working-week pack after PO. Express/air dispatch supported; tell us the shutdown date in the enquiry.

Q6: STA or annealed?
A: Annealed default. STA is not a repair norm for CP Ti — not pre-shipped, re-heat-treat only on written PO.

Q7: Gr5 equipment — can ERTi-2 repair it?
A: No. Gr5 base → ERTi-5 per WPS. Undermatching needs welding-engineer sign-off. Don't mix.

Q8: Orbital weld wire?
A: 1.0–1.6mm level-wound coil, cast/helix matched to feeder. State push/pull/dual at enquiry.

Q9: Medical/FDA claim?
A: No. This is industrial chemical-repair wire (AWS A5.16), not F136 implant chain.

Q10: Quote time?
A: 24h with WPS class + Ø + form + qty + incoterm. Dispatch date written into quote after lot confirm.

Request a Quote

Email: sales@[yourdomain].com

Send WPS filler class + Ø + form + service fluid + shutdown date. Reply in 24h: live lot No., EXW/FOB price, MTC type, dispatch window.


About: Baoji Titanium Valley repair-wire line for chemical service. Pure Gr2 / ERTi-2 per AWS A5.16 — TIG rod + MIG spool, bright-pickled, argon-clean, EN 10204 3.1 with measured interstitials. Matched to Gr2 vessels, exchangers, piping in chloride/brine/seawater. Lot locked before PI; shielding discipline is site-side, wire side is ours. No ghost shelf, no "compatible-grade" stamps.

Получить бесплатное предложение

Опишите ваши требования — марка, размер и количество. Ответим в течение 24 часов.

Captcha code

Предпочитаете чат? WhatsApp +86 188 2967 9311 или напишите на sales@sxqytd.com.

Контактная информация

Контактное лицо: Wang Xiaoning

Телефон: +86-917-355-7966

Эл. почта: sales@sxqytd.com

WhatsApp: +86 188 2967 9311

Компания: Shaanxi Qianyi Tuoda Technology Co., Ltd

Адрес: Floor 4, Building 4, No. 188 Gaoxin Avenue, High-tech Zone, Baoji City, Shaanxi Province, China

Отправить запрос